Deprecated: AbookTableBook::_getAssetParentId(): Implicitly marking parameter $table as nullable is deprecated, the explicit nullable type must be used instead in /home/cvs-host/cvs.spb.su/docs/administrator/components/com_abook/tables/book.php on line 100
Aseismic design and analysis of the primary coolant loop and safety related piping systems of russian design NPP WWER-440
Transactions of PVP ASME Conference, Boston 1999
 
                        - Autors: : Костарев В.В. [Viktor V. Kostarev], Щукин А.Ю. [Alexander Yu. Shchukin], Берковский А.М. [Alexey M. Berkovskiy]
- Publisher: English
- Pages: 5
- N°: 5
- Library: Conference Papers
- Year: 1999
- File: Aseismic_Design_and_Analysis
Hits: 2120
					Review
				
													
					This paper presents the results of seismic analysis of Safety Related Piping Systems of the typical WWER-440 NPP. The methodology of this analysis is based on WANO Terms of Reference and ASME BPVC. The different possibilities for seismic upgrading of Primary Coolant Loop System (PCLS) were considered. The first one is increasing of hydraulic snubber units and the second way is installation of limited number of High Viscous Dampers (HVD).
 CKTI-Vibroseism Ltd.
  CKTI-Vibroseism Ltd.                     





 
                                                            